'Smart Array' is the name used by Hewlett-Packard's line of enterprise-grade RAID controllers.
Download free Android app: the updated guide to 2019. Here are the best alternatives to Aptoide to download paid apps for free and games on Android. Apr 21, 2018 - But you can't get paid apps for free from Play store, also there are some apps like clash of lights are unavailable at play store. How To download paid Apps for Free for Android. Best Method to download Paid Android Apps For Free. No.1) Blackmart Alpha. Tips to use Blackmart:- No.2) Search for the.apk file on Google. Sep 10, 2018 - BlackMart Alpha. BlackMart Alpha could be taken as the alternative to Google play store. It allows downloading any application for free without having to root your device. For free Android app seekers, it's the best destination to get all the apps for free. Get now the Best sites to download paid Android apps & games for free, including GetAPK, APK4Free, 9Apps and 25 other top solutions suggested and ranked. How to download paid games for free on android no root.
1
- HPE ProLiant ML350 G5 Server Models: Access and download drivers. Disk configuration program for Smart Array Controllers and any supported.
- Download the latest drivers for your HP ProLiant ML350 G6. Keep your computer up to date.
HP ProLiant ML350 G10 4U Tower Server - 1 x Intel Xeon Silver 4110 Octa-core (8 Core) 2.10 GHz - 16 GB Installed DDR4 SDRAM - 12Gb/s SAS Controller - 1 x 800 W by HP $2,075.18 $ 2,075.
2answers
HP Smart Array P212 - rebuild Array 1 for OS without loosing Array 2 (Data)
Ok. I'm fairly new to this, but I have a DL180 G6 running with following configuration an HP's P212 Controller:01 Array: 2x 1TB for OS02 Array: 12x 2TB for DataNow I would like to Change both ..
4
4answers
HP DL60 Gen9 not booting installed OS
I have an issue with 2 HP DL60 Gen9 servers. They each contains 2 x 500 G SATA HDDs. I've used Intelligent Provisioning to create a RAID 1 array using the HDDs however, the first issue I noticed is ..
Mugurel73311 gold badge66 silver badges1515 bronze badges
1
1answer
HP Smart Array P212 hangs after firmware update
I’ve just installed a perfect-running HP Smart Array P212 in my server. It comes with 2.72 firmware version.My server runs vmware ESXi 6.0 and, after perform a firmware update to 6.64 version as ..
4
1answer
HP Code 341 “Physical Drive State: Predictive failure. This physical drive is predicted to fail soon.”
this is my first post so bear with me here :-)Background:I have a RAID5 setup with 4 disks that have been working perfect for years.After one drive failed, I installed new drives which where ..
0
1answer
HP DL360 G7 4K native sector disk size compatible?
I have a HP DL360 G7 server with a P410i drive controller which don't accept 4K native sector size disks (Seagate ST2000NX0263). LED on drive bay is red.Is there any controller (Adaptec, LSI, Intel ...
3
1answer
FBWC and Zero Memory (ZM) RAID Controller on HP DL360p
I got a chance to work on HP DL360p Gen8 server with Smart Array controller P420i/ZM What are the advantage of having FBWC or BBWCWill it be possible to add an external P420/1GB or P420/2GB to this ..
1
4answers
hp proliant not recognizing emc sas drives
We have lots of 2.5' SAS drives from a decomissioned EMC AX4 array (Seagate Savvio 10k.3), and would like to install on HP Proliant 360pG7. Proliant does not detect those drives, is there something ..
0
1answer
HP ML360 G6 server won't boot after swapping system disk
![Hp proliant ml350 g6 support Hp proliant ml350 g6 support](/uploads/1/2/4/4/124440260/555939024.jpg)
I am hoping for some help since I am completely out of ideas how to solve this!I have a ML360 G6 server with a smartarray p410 controller.All disks conifured in 4 separate arrays in raid 0 (I know, ..
1
0answers
Connect external 4-bay SAS enclosure to HP SAS Expander Card?
I've got an HP DL380 G7 with the HP SAS Expander Card. The server has 16 internal drive bays, which are all populated. It also has an external SAS connector on the expander card.I have an external 4-..
1
1answer
CentOS 7 DL120 G9 with H240 - Monitoring RAID Issue
I have just configured a new server using a Smart HBA H240 card and installed hpssaducli and it detects the controller and allows me to generate a report.The issue that I am having is how can I ..
1
1answer
Samsung SM863 SSD disk in HP ProLiant DL380 Gen9
Does anyone have any experience on using Samsung SSD disks in HP servers?I am planning to buy the following: ProLiant DL380 Gen9 Xeon E5-2620 v3 (Disk controller: Smart Array P440ar with 2GB FBWC)..
1
2answers
HDD in RAID 1 Migration. SmartArray P410i to SmartArray P420i
I have a failed HP ProLiant ML350 Gen6 server (power surge fried the motherboard). It has an embedded SmartArray P410i controller. I also have a HP ProLiant ML350P Gen8 server with an embedded ..
3
2answers
What RAID configuration do I actually have?
So lately I've been playing around with my recently purchased (used server) (HP ProLiant ML330 G6) and I am a bit confused as to the current RAID configuration it has. I did a bit of checking via the ..
4
3answers
Hardware RAID1 configuration - Possibly failed sectors on one physical disk. Does the OS automatically read from the other disk?
I'm not a professional sysadmin but since I couldn't find answers to my specific case after researching for a while I was hoping I could get some help here. Our server uses P222 - a HP Smart ..
5
0answers
HP MSA P2000 G3 Disk Scrubbing performance?
I have a HP P2000 G3 array with two 10Gbit iSCSI controllers in it that presents storage to my virtualisation cluster. It is soon to be expanded with two D2700 shelves each loaded with 25 10k RPM ..
1
1answer
Debian Wheezy drivers for HP ProLiant DL360 Gen9 RAID controller
good morning everyone!I bought 2 HP DL360 Gen9 Servers and wanted install Debian Wheezy on those with PXE Boot network install. But it seems that Wheezy does not include a driver for the Smart Array ..
0
0answers
HP Array Utility, Remove a spare drive from a Raid 1 Array
I have a DL380 with 2 Raid 1 arrays with spares. As the server is a part of a cluster I want to remove the spares and create a new logical drive with them. The problem is that HP Array Configuration ..
1
1answer
Configure more than two logical drives in an HP ProLiant Gen8 server?
I've a server HP Proliant dl380 gen 8. I've got 2 RAID 1 drives (each having 2 HDDs (300gb) in a mirror). I've now come to put 4 extra physical disks into the server and it won't let me create the ..
1
1answer
How to connect HP MSA2324sa to server?
I'm having issues with an HP MSA2324sa array. I connected it to the server and the server does see it however, I am not getting a /dev/s* device even though I have properly mapped the host from the ..
Mugurel73311 gold badge66 silver badges1515 bronze badges
3
4answers
P410i smart array controller SATA drive recommendations of known working models
Background:my company needed some internal, reliable servers for internal data. (we normally use cloud).Being a small company, we have scanty budget, but also flexibility.We picked up a number ..
1
3answers
HP Proliant - RAID 5 array recovery
I searched but found no solution to this question.I have a HP ProLiant DL385-G5p server with RAID 5, having 4 hard drives: 3*75GB + 1*75GB spare.One of the 3 hard disks in RAID5 has failed (the ..
2
1answer
ProLiant SE316M1 + Intel S3500 SSD + Smart Array P410 512MB. Battery (BBWC) needed? [duplicate]
I'm looking to replace our SQL Server: HP Proliant DL360 G4 2x 64-bit Intel Xeon 3.60 GHz, 1M Cache, 800 MHz FSB 4GB RAM DDR2 HP Smart Array 6i 2x 146GB SCSI 15K (RAID 1) With this: HP ..
2
1answer
What could be wrong with our HP Proliant Server [closed]
While observing our file server yesterday, I witnessed a BSOD, and after a restart, the Server OS (2003) cant boot. We have 6 raid drives. I noticed the disk lights and discovered the first four from ..
2
1answer
HP Smart Array B110i SATA RAID Controller drivers crash HP DL320 G6
I'm trying to install Windows Server 2012R2 on a HP DL320 G6 with a Smart Array B110i SATA RAID Controller. During the install, it asks me to load the driver for the RAID, I load the drivers from ..
Guillaume Filion80411 gold badge99 silver badges1212 bronze badges
4
2answers
Identify which drives belong to a specific HP RAID 5 Group
A total of 32 drives were removed from x4 decommissioned HP DL380 G6 servers (eight per server).The setup of the eight drives per host was into two RAID Groups:RAID 1 = SLOT 1, 2 = ESXi OSRAID 5 = ..
2
2answers
RAID1 drive not seen by CentOS 7 Installer on HP ProLiant DL360e Gen8
I need to install CentOS 7 on a HP ProLiant DL360e Gen8 server. The RAID1 has been configured in the bios: I have downloaded the driver from http://downloads.linux.hp.com/repo/spp/rhel/7/x86_64/..
-2
1answer
HP Proliant DL380 Gen9 [closed]
I have HP proliant DL380 Gen9 I do the installation oracle linux 6.4 and installation does not detect the logical drive created. i have 300GB SAS- on raid 0 logical drive
3
1answer
HP Proliant DL360 G6 Maximum Logical Drives
I have an HP Proliant DL360 G6 server with 8 HD bays. Currently I have the first two bays working with ESXi and I'm just running RAID 0 on a single drive. This is not a production machine. It has a ..
-1
1answer
HP Smart Array 6i upgrade firmware on Ubuntu
How can I upgrade the firmware of my HP Array controller 6i? can I upgrade using hpacucli? or any other CLI utility? The server that I want to upgrade is a HP Proliant DL360 G4 with Ubuntu Server..
0
1answer
HP DL180 G6 - SD Card slot
I have ESXi 5 installed on HP DL180 G6 on RAID. This server is part of the vCenter and it's connected with HP P2000 Storage. For some reason all VMs on that server a very slow and 'restart' of the ..
0
1answer
Adding additional hot swap drive to HP ProLiant DL360 in RAID1 config
I have a HP ProLiant DL360p Gen8 server. It has 8 drive bays with only 6 being used in a RAID1 config. Can I add an additional 2 drives to the empty bays hot and the HP Smart Array Controller will ..
3
2answers
HP B120i RAID0 very slow to read data from disks
I have a HP DL320e g8 v2 server running CentOS 7.1 (kernel 3.10.0-229.4.2.el7.x86_64). This server comes with a B120i onboard SmartArray controller, and it was configured with two identical 3TB ..
0
![Sas Sas](/uploads/1/2/4/4/124440260/812178113.jpg)
3answers
Hp Ml350 G6 Drivers
HP array device fails after pci slot change
i changed my HP 410 smart array controller from one pci slot to another because it was faulty. After the change the logical unit i had fails showing one disk as unassigned and a new one into the array..
1
3answers
Migrate SAS disks from E200i to B320i Smart Array
I have an older HP ML350 G5 series server with 4 SAS 72GB hdds in RAID 0+1. It's down and beyond repair. So I was wondering would it work if I was just to plug those in newer server with B320i RAID ..
2
2answers
HP DL180 G6 - Are 6G/s speeds obtainable?
I have a DL180 G6 server with 12x 2Tb 6G/s SAS drives. I was only getting 3G/s reported. I then went and purchased a P410 controller with 512 Meg cache and battery.I loaded up the drives with Server ..
1
2answers
Raid 6 with HP P421?
I cant figure out if I need to buy a licens key to enable Raid 6 for this raid controller? I can't find where to buy one and I find pages where it says that its now free.sudo hpssacli ctrl slot=1 ..
4
2answers
Extended raid 5 is not expanding
I have a D2700 with 25 1Tb disks with a P421 raid card in a dl360p gen8 HP server.It was raided as two raid 5 with 2 spare each. I decided to make one raid 5 out of them, deleted one raid and added ..
2
1answer
Can I Use a Normal SSD disk in HP DL380 G6
We have a bunch of DL-380 G6 servers in our company, I want to know whether it is possible to use 2.5' SSD hard drives (with SATA III interface) on these servers or not?
2
1answer
HP 420i disk controller in Gen8 ProLiant fails to detect third-party disks
I have some fresh out of the box HP Proliant Generation 8 servers which have the HP 420i disk controllers built into the motherboard. Once upon a time the disk controller was a PCI card but now in Gen ..
4
2answers
Samsung 850 EVO + HP P410 limited iops?
I´m experiencing a weird write iops limitation with a HP P410 256mb cache controller and 4x consumer grade ssd´s (Samsung EVO 850) in RAID5/10. After upgrade to latest firmware (6.64) for HP P410 ..
7
2answers
Storage issues: Prolonging the life of a legacy Compaq ML370
I have an original ML370, from before there even were generations (2000). The storage system is comprised of a Smart Array 431 controller, 2 9.1 Gb Ultra3 SCSI (COMPAQ BD009635C3), and 4 146.8 Gb ..
3
1answer
Install GNU/Linux No System Disk Error — HP Smart Array
I have a HP Proliant DL360 g5, and am trying to install archlinux. It has a HP Smart array controller with 6 drives (all green) creating two logical volumes (one volume with 5 RAID6 drives, and the ..
2
1answer
HP ProLiant - GNU/Linux - Can't find RAID drives
I have a ProLiant DL360 G5. I would like to install Arch Linux onto this machine, but I'm experiencing the following difficulties:I have booted Arch Linux installation CD, but I can't seem to access ..
1
1answer
HP DL360 G5 RAID controller not recognizing drive bays 5 and 6
I have an HP DL360g5 bios P58. With a Slot 0, HP Smart Array P400i Controller (256MB v2.08)The server originally was running Windows Server 2003 with 2 72GB 15k SAS drives in RAID0. One of the ..
-5
1answer
HP's $1,000 RAID Controller is outclassed by on-board raid? [closed]
HP's $1,000 Smart Array P822 controller is outclassed by an on-board raid controller. I'm having a hell of a time trying to figure this one out. My problem is that performance on the HP controller is ..
0
3answers
HP Smart Array - create a logical drive with a physical drive that contains data
I'm using a server with a HP Smart Array controller.I have a hard drive that I wrote data to. I would like to install that disk in the server and use it.Is it possible to create a logical drive ..
2
2answers
How do I override grsec?
After a reboot recently, I have a pair of servers that are now unable to monitor their disk status. Nagios reports:HP RAID ArrayUNKNOWN Error: No controllers detected. -/-/- (LD : []) I get the ..
jldugger9,4111818 gold badges6767 silver badges120120 bronze badges
3
1answer
How do I install HP Smart Storage Administrator (hpssa) on a Proliant N40L running Ubuntu Server 14.10?
I have an HP Proliant N40L MicroServer with an HP Smart Array P410 raid card. The boot drive is an SSD running Ubuntu Server 14.10.The P410 is getting hung up while initializing. From what I've read,..
1
1answer
Smart Array E200i battery on ML350 G5 did not fix the warning message (battery failure)
I have got this warning message on the System Management in a Proliant server ML350 G5.Degraded AcceleratorName ValueStatus: Temporarily DisabledError Code: Cache Disabled Low BatteriesSerial ..
6
1answer
Expand RAID array on HP Dynamic Smart Array B320i controller
I have a few HP ProLiant DL360e Gen8 servers that are equipped with the Dynamic Smart Array B320i RAID controller. One particular system was shipped with a single disk installed instead of a pair of ..
Hp Proliant Ml350 G6 Support
ewwhite176k8080 gold badges380380 silver badges734734 bronze badges
prev 12345…9 next
Hp Proliant Ml350 G5 Server
I have one HP server proliant ML350 G6 with OS windows 2008 standard edition installed. I would like downgrade the OS and Microsoft could let me a Kit for the operation with windows server 2003 R2 standard edition. Now I have a doubt for the drivers compatibility. In fact on the page of the product there are Windows Server 2003 and the 64-bit Extended Systems. I think that Win server 2003 and Win server 2003 R2 are different by the kernel and I suppose I will have problem for driver compatibility.What do think about?
best regards, Download game app on windows 10.
massimo
maximmaxim
1 Answer
2003 R2 was not a kernel change. The drivers would be the same as for 2003.
VER on Windows 2003 R2 reports the same as 2003: Microsoft Windows [Version 5.2.3790]
2008 R2 is however very much different from 2008.
If you are not using the HP installation CD, you may need to install using a floppy drive if you want to have the latest storage driver from the start or the Windows media does not recognize the storage controllers. During setup, you would press F6 when prompted, to install a different storage controller driver. Of course with modern hardware, that would be a USB floppy drive.
Greg AskewGreg Askew29.4k33 gold badges3838 silver badges7070 bronze badges